Asus GIGAX2048 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Redes Asus GIGAX2048. Asus GIGAX2048 User manual [en] [fr] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - GigaX2024/2048

GigaX2024/2048User ManualLayer 2 Managed Switch

Página 2

GigaX2024/2048 L2 Managed Switch User ManualviiiFigure 29. IGMP Snooping ...

Página 3

88GigaX2024/2048 L2 Managed Switch User ManualSubnet masks are used to define subnets (what you get after dividing a network into smaller pieces). A su

Página 4 - ASUS contact information

89 GigaX2024/2048 L2 Managed Switch User Manual7 TroubleshootingThis section gives instructions for using several IP utilities to diagnose problems. A

Página 5 - Table of Contents

90GigaX2024/2048 L2 Managed Switch User Manual(using the pre-configured default LAN IP address 192.168.1.1) or another address you assigned.You can als

Página 6

91 GigaX2024/2048 L2 Managed Switch User Manual 7.2 Replacing defective fansTurn off the power of the switch when you remove the fan module on the rea

Página 7

92GigaX2024/2048 L2 Managed Switch User ManualFigure 74. Detaching the fan from the module5. Fasten the new fan with the screws that you removed earli

Página 8

93 GigaX2024/2048 L2 Managed Switch User Manual7.3 Simple fixesThe following table lists some common problems that you may encounter when installing or

Página 9 - List of Figures

94GigaX2024/2048 L2 Managed Switch User ManualProblem Suggested ActionPCs cannot display web configuration pages.1.The switch is powered up and the co

Página 10

95 GigaX2024/2048 L2 Managed Switch User Manual8 Glossary10BASE-T A designation for the type of wiring used by Ethernet networks with a data rate of

Página 11

96GigaX2024/2048 L2 Managed Switch User Manualfiltering rule A rule that specifies what kinds of data the a routing device will accept and/or reject. F

Página 12 - List of Tables

97 GigaX2024/2048 L2 Managed Switch User Manuale.g., 209.191.4.240. An IP address consists of a network ID that identifies the particular network the h

Página 13 - 1 Introduction

GigaX2024/2048 L2 Managed Switch User ManualixFigure 58. Policy Set ...

Página 14 - 1.2.1 Notations

98GigaX2024/2048 L2 Managed Switch User Manualbinary, IP address, subnet, “IP Addresses Explained” section.NIC Network Interface Card An adapter car

Página 15 - 2 Getting to know the GigaX

99 GigaX2024/2048 L2 Managed Switch User Manualperforms routing is called a router.SNMP Simple Network Management Protocol The TCP/IP protocol used

Página 16 - 2.2 Front Panel

100GigaX2024/2048 L2 Managed Switch User Manualthat receives a packet decrements this field by one. When the TTL reaches zero, the packet is discarded.

Página 17 - 2.4 Technical specifications

101 GigaX2024/2048 L2 Managed Switch User Manual9 Index100BASE-T, 9510BASE-T, 95Administration page, 19Binary numbers, 95Bits, 95Boot Rom Command Mode

Página 18 - 3 Quick start guide

102GigaX2024/2048 L2 Managed Switch User ManualMirror Commands, 62Mirroring page, 23Multicast Commands, 63Network. See LANNetwork classes, 87Network I

Página 19 - 3.2.3 Attach the RPS module

103 GigaX2024/2048 L2 Managed Switch User ManualWAN, 100Web browser, 100Web function layout, 12Web Interface, 12Web page, 100Web site, 100Web top fram

Página 20 - Table 4. LED Indicators

GigaX2024/2048 L2 Managed Switch User ManualxList of TablesTable 1. Front panel labels and LEDs ...

Página 21

1 GigaX2024/2048 L2 Managed Switch User Manual1 IntroductionCongratulations on becoming the owner of the ASUS GigaX2024/2048 Layer 2 managed switch! Y

Página 22

2GigaX2024/2048 L2 Managed Switch User Manual• Enterprise MIB for PSU, fan, and system temperature, voltage• Telnet or SSH2 remote login• FTP for fi

Página 23

3 GigaX2024/2048 L2 Managed Switch User Manual2 Getting to know the GigaX2.1 Package contentsThe GigaX2024/2048 switch package comes with the followi

Página 24

4GigaX2024/2048 L2 Managed Switch User Manual2.2 Front PanelThe front panel includes 24/48 RJ-45 10/100Base-T ports, two 10/100/1000Base-T ports, two

Página 25

5 GigaX2024/2048 L2 Managed Switch User Manual2.3 Rear PanelThe switch rear panel contains the fan modules, two console ports (USB and DB9) and one RP

Página 26 - 4.2 Functional layout

6GigaX2024/2048 L2 Managed Switch User Manual3 Quick start guideThis section provides the basic instructions to set up the switch environment. Refer a

Página 27 - 4.2.1 Menu navigation tips

7 GigaX2024/2048 L2 Managed Switch User Manual3.2.2 Connect to the computers or a LANYou can use Ethernet cable to connect computers, hubs and other s

Página 28 - 4.3 System Pages

E2301October 2005 V2.3 Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software describ

Página 29 - 4.3.2 IP Setup

8GigaX2024/2048 L2 Managed Switch User ManualTable 4. LED IndicatorsNo. LED Description1 System Solid green indicates that the switch is turned on. If

Página 30 - 4.3.5 Firmware Upgrade

9 GigaX2024/2048 L2 Managed Switch User Manual5. Type “login” to access the command line interface. The default user name is “admin”. Skip the passwor

Página 31 - 4.4 Physical Interface

10GigaX2024/2048 L2 Managed Switch User ManualThis is the factory default IP address of the switch.A login screen appears, as shown in Figure 7. Figur

Página 32 - 4.5 Bridge

11 GigaX2024/2048 L2 Managed Switch User ManualFigure 8.IP Setup (GigaX 2048) Figure 9.IP Setup (GigaX 2024)

Página 33 - 4.5.2 Link Aggregation

12GigaX2024/2048 L2 Managed Switch User Manual4 Management with the Web InterfaceThe switch provides Web pages that allow switch management through th

Página 34

13 GigaX2024/2048 L2 Managed Switch User ManualFigure 11. Home page (GigaX 2048) Figure 12. Home page (GigaX 2024)

Página 35 - 4.5.3 Mirroring

14GigaX2024/2048 L2 Managed Switch User Manual4.2 Functional layoutThe web-based configuration page consists of three separate frames. The top frame ha

Página 36 - 4.5.4 Static Multicast

15 GigaX2024/2048 L2 Managed Switch User ManualFigure 15. Expanded Menu ListThe above frame displays configuration pages or graphics for the statistics

Página 37 - 4.5.6 Traffic Control

16GigaX2024/2048 L2 Managed Switch User Manual4.2.2 Commonly used buttons and iconsThe following table describes the function for each button and icon

Página 38 - 4.5.7 Dynamic Addresses

17 GigaX2024/2048 L2 Managed Switch User ManualFigure 16. Management4.3.2 IP SetupThe switch supports dynamic IP and static IP assignment. Dynamic IP

Página 39 - 4.5.9 Tagged VLAN

GigaX2024/2048 L2 Managed Switch User ManualiFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation

Página 40

18GigaX2024/2048 L2 Managed Switch User Manual4.3.3 Administration The Administration page allows to enable or disable the password protection for web

Página 41

19 GigaX2024/2048 L2 Managed Switch User ManualEnter the firmware (or auto-config file) location into the firmware space directly, or click Browse... to c

Página 42 - 4.5.11 DHCP Snooping

20GigaX2024/2048 L2 Managed Switch User ManualSelect the corresponding port and configure the port setting, then click on the Modify button. The field y

Página 43 - 4.6 SNMP

21 GigaX2024/2048 L2 Managed Switch User ManualPriority: the port priority in the switch. Low numeric value indicates a high priority. The port with l

Página 44 - 4.6.4 VACM Group

22GigaX2024/2048 L2 Managed Switch User Manualof the link aggregation group according to source MAC address, destination MAC address, source and desti

Página 45 - 4.6.5 VACM View

23 GigaX2024/2048 L2 Managed Switch User Manual Figure 23. Link aggregation (GigaX 2048)Figure 24. Link aggregation (GigaX 2024)4.5.3 MirroringMirrori

Página 46 - 4.6.6 USM User

24GigaX2024/2048 L2 Managed Switch User Manual Figure 25. Mirroring page (GigaX 2048) Figure 26. Mirroring page (GigaX 2024) 4.5.4 Static MulticastT

Página 47 - 4.7 Filters

25 GigaX2024/2048 L2 Managed Switch User ManualFigure 27. Static Multicast (GigaX 2048)Figure 28. Static Multicast (GigaX 2024)4.5.5 IGMP SnoopingIG

Página 48 - Figure 44. Filter Set

26GigaX2024/2048 L2 Managed Switch User Manualthe limit value. Traffic control does not work for isolated port of Private VLAN.Click OK to make the set

Página 49 - 4.7.2 Filter Attach

27 GigaX2024/2048 L2 Managed Switch User Manual4.5.8 Static AddressesYou can add a MAC address into the switch address table. The MAC address added by

Página 50 - 4.8 Security

GigaX2024/2048 L2 Managed Switch User ManualiiASUS contact informationASUSTeK COMPUTER INC. (Asia-Pacific)Address: 150 Li-Te Road, Peitou, Taipei, Tai

Página 51

28GigaX2024/2048 L2 Managed Switch User Manual“T” type: All packets transmitted from this port will be tagged.“blank” type: This port is not a member

Página 52 - 4.8.3 RADIUS

29 GigaX2024/2048 L2 Managed Switch User ManualFigure 33. Tagged VLAN (GigaX 2048) Figure 34. Tagged VLAN (GigaX 2024)4.5.10 Default Port VLAN and Co

Página 53 - 4.8.4 Port Security

30GigaX2024/2048 L2 Managed Switch User ManualFigure 35. Default Port VLAN and CoS 4.5.11 DHCP SnoopingDHCP snooping is a DHCP security feature that

Página 54 - 4.8.4.2 Port Status

31 GigaX2024/2048 L2 Managed Switch User Manual4.6 SNMPThis group offers the SNMP configuration including Community Table, Host Table, and Trap Setting

Página 55 - Figure 53. Port Status

32GigaX2024/2048 L2 Managed Switch User Manual4.6.3 Trap SettingBy setting trap destination IP addresses and community names, you can enable SNMP trap

Página 56 - 4.8.4.3 Secure MAC Addresses

33 GigaX2024/2048 L2 Managed Switch User ManualYou can remove the existed group by selecting the entry with the mouse, then clicking on Remove. The Mo

Página 57 - 4.9.1 Trust State

34GigaX2024/2048 L2 Managed Switch User Manualgo to Save Configuration page, then click on Save. Figure 42. VACM View4.6.6 USM UserUSM(User-based Secur

Página 58 - 4.9.3 Class Set

35 GigaX2024/2048 L2 Managed Switch User ManualFigure 43. USM User4.7 FiltersThe switch can filter certain traffic types according to packet header info

Página 59 - 4.9.4 Policy Set

36GigaX2024/2048 L2 Managed Switch User ManualFigure 44. Filter SetThe Filter Rule page provides options for rule modes, one is MAC rule (Figure 40) a

Página 60 - Figure 58. Policy Set

37 GigaX2024/2048 L2 Managed Switch User Manual4.7.2 Filter AttachA filter set is idle if you did not attach it to any ingress or egress port. Use the

Página 61 - 4.9.6 CoS

GigaX2024/2048 L2 Managed Switch User ManualiiiTable of Contents1 Introduction ...

Página 62 - 4.10 Statistics Chart

38GigaX2024/2048 L2 Managed Switch User ManualFigure 48. Filter Attach (GigaX 2024) 4.8 SecurityThe switch has the 802.1x port-based security feature.

Página 63 - 4.10.2 Error Group

39 GigaX2024/2048 L2 Managed Switch User ManualQuiet Period: If authentication failed either from RADIUS or local database, the switch waits upon this

Página 64 - 4.10.3 Historical Status

40GigaX2024/2048 L2 Managed Switch User Manual4.8.2 Dial-In UserDial-in User is used to define users in the local database of the switch. User Name: Ne

Página 65 - 4.11 Save Configuration

41 GigaX2024/2048 L2 Managed Switch User ManualClick OK to make the setting send to the switch (HTTP server). Click Reload to refresh the settings to

Página 66 - 5 Console Interface

42GigaX2024/2048 L2 Managed Switch User Manualaging mechanism is only effective for dynamic secure MAC addresses. If the time is equal to 0, the aging

Página 67 - 5.1.2 Boot ROM Commands

43 GigaX2024/2048 L2 Managed Switch User Manualthe violation mode is ʻrestrictʼ. e) Shutdown: this indicates that the port is shutdown due to port sec

Página 68 - Table 7. Boot ROM commands

44GigaX2024/2048 L2 Managed Switch User Manual4.8.4.3 Secure MAC AddressesUsers can add a MAC address into the secure MAC address table of one port. T

Página 69 - 5.3 CLI Commands

45 GigaX2024/2048 L2 Managed Switch User Manual4.9.1 Trust StateThis page is used to configure packets classification using port trust states. Users can

Página 70 - Figure 69. SYS commands

46GigaX2024/2048 L2 Managed Switch User ManualFigure 55. Trust State4.9.2 MappingThis page is used to configure CoS (Classification of Service) and DSCP

Página 71

47 GigaX2024/2048 L2 Managed Switch User Manualtraffic. The class set defines the criteria (match mode) used to match a specific traffic flow to further cl

Página 72 - 5.3.3 Bridge Commands

GigaX2024/2048 L2 Managed Switch User Manualiv4.2.2 Commonly used buttons and icons ... 164.3 System Pages

Página 73

48GigaX2024/2048 L2 Managed Switch User Manualjust click on to select the policy that you want to edit or remove. And then click on Edit to enter th

Página 74

49 GigaX2024/2048 L2 Managed Switch User ManualFigure 59. Policy Edit4.9.5 Policy AttachA policy does nothing if you donʼt attach it to any ingress po

Página 75 - **For GigaX 2024

50GigaX2024/2048 L2 Managed Switch User ManualWeighted round-robin (WRR) scheduling: WRR scheduling requires you to specify a number the indicates the

Página 76

51 GigaX2024/2048 L2 Managed Switch User Manual Figure 62. Traffic comparison (GigaX 2048) Figure 63. Traffic comparison (GigaX 2024)4.10.2 Error Group

Página 77

52GigaX2024/2048 L2 Managed Switch User Manual Figure 64. Error group4.10.3 Historical StatusYou can display information for different ports and stat

Página 78

53 GigaX2024/2048 L2 Managed Switch User Manual4.11 Save Configuration To save configuration permanently, you have to click Save. The setting also takes

Página 79

54GigaX2024/2048 L2 Managed Switch User Manual5 Console InterfaceThis chapter describes how to use console interface to configure the switch. The switc

Página 80 - 5.3.4 SNMP

55 GigaX2024/2048 L2 Managed Switch User Manual5.1.1 Boot ROM Command ModeDuring the POST process, you can enter a Boot ROM Command mode by pressing &

Página 81

56GigaX2024/2048 L2 Managed Switch User ManualTable 7. Boot ROM commandsCommand Parameters Usage Notesd Address [,length]Dump memory contents by givin

Página 82

57 GigaX2024/2048 L2 Managed Switch User Manual5.2 Login and LogoutBy typing login to enter the CLI mode, you have to give a valid user name and passw

Página 83

GigaX2024/2048 L2 Managed Switch User Manualv4.7.2 Filter Attach ...

Página 84

58GigaX2024/2048 L2 Managed Switch User ManualIf you put the contact description in the contact description field, the switch contact will change to th

Página 85

59 GigaX2024/2048 L2 Managed Switch User ManualIP address.CLI command: net interface ip sw0 < IP address> <netmask>[Network Mask]Displays

Página 86 - 5.3.5 Filters Commands

60GigaX2024/2048 L2 Managed Switch User Manual5.3.2 Physical Interface Commands[Admin] [Enable/Disable]Displays the port admin status, allow user to t

Página 87

61 GigaX2024/2048 L2 Managed Switch User ManualCLI command: l2 stp bridge setHello Time (1..10 seconds): [old Hello Time] <new Hello Time>Forwar

Página 88

62GigaX2024/2048 L2 Managed Switch User Manual[Create Trunk]Creates a new trunk group by giving trunk ID, rtag, name , LACP mode and port numbers. The

Página 89 - 5.3.6 Security Commands

63 GigaX2024/2048 L2 Managed Switch User Manual**For GigaX 2048[Mirror] [Mirror 1/Mirror 2] [Mirror Mode] [Enable/Disable][Monitor Port] [port number]

Página 90

64GigaX2024/2048 L2 Managed Switch User Manual[MAC Address][VLAN][CoS] [0-7]Allows user to add or modify a static multicast group by specifying the MA

Página 91

65 GigaX2024/2048 L2 Managed Switch User Manual[Multicast] [Enabled/Disabled][Destination Lookup Failure] [Enabled/Disabled]User can limit the broadca

Página 92

66GigaX2024/2048 L2 Managed Switch User Manual[Discard] [none/source/destination/source & destination]User can add or modify a static ARL entry by

Página 93

67 GigaX2024/2048 L2 Managed Switch User ManualCLI command: l2 dhcpsnoop enable <vlan id list>CLI command: l2 dhcpsnoop disable <vlan id list

Página 94 - 5.3.7 QoS Commands

GigaX2024/2048 L2 Managed Switch User Manualvi5.3.3 Bridge Commands ... 605.3.4

Página 95

68GigaX2024/2048 L2 Managed Switch User Manual[DHCP Snooping is]Enable or disable DHCP snooping on specific VLAN.CLI command: l2 dhcpsnoop enable <v

Página 96

69 GigaX2024/2048 L2 Managed Switch User ManualCLI command: snmp community deleteAllows user to delete a community entry from community table.Communit

Página 97 - 5.4 Miscellaneous Commands

70GigaX2024/2048 L2 Managed Switch User Manual[Destination][Community for Trap]A trap entry contains SNMP version (currently support version 1 and ver

Página 98 - 6.1 IP Addresses

71 GigaX2024/2048 L2 Managed Switch User Manualsecurity level and context match.CLI command: snmp snmpv3 access addGruop Name: <group name string&g

Página 99 - 6.2 Subnet masks

72GigaX2024/2048 L2 Managed Switch User Manual[View Subtree][View Mask]VACM(View-based Access Control Model) View is used to view the information of S

Página 100

73 GigaX2024/2048 L2 Managed Switch User ManualUSM(User-based Security Model) User is used to configure the information of SNMPV3 USM User. A USM User

Página 101 - 7 Troubleshooting

74GigaX2024/2048 L2 Managed Switch User Manual5.3.5 Filters Commands[New] Creates a new filter set with specifying a unique ACL ID and its description

Página 102 - 7.1.2 nslookup

75 GigaX2024/2048 L2 Managed Switch User Manual[Destination Port] [Type/Port][Protocol] [ICMP/TCP/UDP/ANY][Add]User can add a new IP rule associated t

Página 103 - 7.2 Replacing defective fans

76GigaX2024/2048 L2 Managed Switch User Manual[Destination Port] [Type/Port][Protocol] [ICMP/TCP/UDP/ANY][Modify]Allows user to modify the IP filter ru

Página 104

77 GigaX2024/2048 L2 Managed Switch User Manual[Rule List]Displays the filter set and filter rule configurations.CLI command: filter rule show <set id&

Página 105 - 7.3 Simple fixes

GigaX2024/2048 L2 Managed Switch User ManualviiList of FiguresFigure 1. GigaX L2 managed switch package contents ...

Página 106

78GigaX2024/2048 L2 Managed Switch User Manual[Quiet Period]Allows user to set up the quiet period.CLI command: security dot1x bridge quietperiod <

Página 107 - 8 Glossary

79 GigaX2024/2048 L2 Managed Switch User Manual[Dynamic VLAN]Create users in the local database of the switch for 802.1x authentication. A user entry

Página 108

80GigaX2024/2048 L2 Managed Switch User Manualconfirm authentication key <key/none>: <confirm server key>[Reload]Restores the previous saved

Página 109

81 GigaX2024/2048 L2 Managed Switch User ManualAllows user to set up the aging time of some particular ports.CLI command: security portsecu age <ag

Página 110

82GigaX2024/2048 L2 Managed Switch User Manual5.3.7 QoS Commands[State] [No/CoS/DSCP]Allows users to set up trust state of some particular ports.CLI c

Página 111

83 GigaX2024/2048 L2 Managed Switch User ManualAllows users to modify a match criterion of a class. If users input <new dscp list>, <new acl

Página 112

84GigaX2024/2048 L2 Managed Switch User ManualCLI command: qos policy add <policy id(1-56)> <class id(1-56)>dscp (0/8/10/16/18/24/26/32/34

Página 113

85 GigaX2024/2048 L2 Managed Switch User Manual[CoS Queue ][Weight]Set the scheduler mode. The weight delay of queues only effective for weighted roun

Página 114

86GigaX2024/2048 L2 Managed Switch User Manual6 IP Addresses, Network Masks, and Subnets6.1 IP AddressesThis section pertains only to IP addresses for

Página 115

87 GigaX2024/2048 L2 Managed Switch User ManualFollowing are examples of valid IP addresses:Class A: 10.30.6.125 (network = 10, host = 30.6.125)Class

Comentários a estes Manuais

Sem comentários