ASUS Storage DS300 G2 Series

Página 2 - Contents

DS300f G2 Series User Manual 4arChIteCtural desCrIptIonThe ASUS DS300f G2 subsystems are suitable for Direct Attached Storage (DAS), Storage Area Net

Página 3

DS300f G2 Series User Manual 94runnInG meDIa Patrol on a DISk arrayMedia Patrol is a routine maintenance procedure that checks the magnetic media on

Página 4

DS300f G2 Series User Manual 95PreParInG a DISk array for tranSPortThis feature prepares the physical drives that make up the disk array to be remove

Página 5

DS300f G2 Series User Manual 96ManaGInG loGICal drIvesLogical drive management includes:• "Viewing a List of Logical Drives" on page 96•

Página 6

DS300f G2 Series User Manual 97vIewInG loGIcal DrIve StatIStIcSTo view logical drive statistics:1. Click the Storage tab.2. Click the Logical Drive

Página 7 - Chapter 1: IntroduCtIon

DS300f G2 Series User Manual 989. Foreachofthefollowingitems,acceptthedefaultorchangethesettingsasrequired:• ChooseaStripesize.64

Página 8

DS300f G2 Series User Manual 993. Clickthelogicaldriveyouwant,thenclicktheLocate button.ThedrivecarrierstatusLEDsofthediskcarriers

Página 9 - AdvAnced bAttery flAsh bAckuP

DS300f G2 Series User Manual 100mIGratInG a loGIcal DrIve’S raID levelTheterm“Migration”meanseitherorbothofthefollowing:• Change the RAID l

Página 10

DS300f G2 Series User Manual 1016. Click the Start button to begin the cloning process.The cloning progress bar displays.Note the Target Logical Dri

Página 11

DS300f G2 Series User Manual 102vIewInG SPare DrIve InformatIonTo view spare drive information:1. Click the Storage tab.2. Click the Spare Drive ic

Página 12 - PeratIonal featureS

DS300f G2 Series User Manual 103locatInG a SPare DrIveSpare drives are located in the same way as individual physical drives.To locate a spare drive:

Página 14 - Core Platform

DS300f G2 Series User Manual 104ManaGInG InItIatorsInitiator management includes:• "Viewing a List of Initiators" on page 104• "Addi

Página 15 - General speCIfICatIons

DS300f G2 Series User Manual 105aDDInG an IScSI InItIatorTo add an iSCSI initiator to the list: 1. Click the Storage tab.2. Click the Initiator ico

Página 16 - Arnings And cAutions

DS300f G2 Series User Manual 106aDDInG a lun maPForFCsystemsoriSCSIsystems,youcansetupanInitiatorLUNmap.A maximum of 256 logical drives

Página 17 - ArrAnty And suPPort

DS300f G2 Series User Manual 107DeletInG a lun maPDeleting a LUN map prevents the initiator from accessing the LUN while LUN masking is enabled.To de

Página 18

DS300f G2 Series User Manual 108NoteInsomecases,HBAsettingstoN-Portonlyworkifconnectedtotheswitch.RefertoyourHBA manual for more inf

Página 19

DS300f G2 Series User Manual 109vIewInG a lISt of fc loGGeD-In DevIceSLogged-indevicesreferstoallFibreChanneldevicescurrentlyloggedintothe

Página 20 - Cautions

DS300f G2 Series User Manual 110vIewInG a lISt of IScSI tarGetSA targetisalogicaldeviceontheASUSDS300fG2subsystem.Thedefaulttargetexpos

Página 21

DS300f G2 Series User Manual 111makInG IScSI tarGet SettInGSTo make target settings:1. Click the Device tab.2. Click the iSCSI Management icon.3.

Página 22 - InstallInG physICal drIves

DS300f G2 Series User Manual 112To add a portal:1. Click the Device tab.2. Click the iSCSI Management icon.3. Click the Portal tab.4. Click the C

Página 23 - InStallInG your DrIveS

DS300f G2 Series User Manual 113vIewInG IScSI Port InformatIonTo view information about a port:1. Click the Device tab.2. Click the iSCSI Managemen

Página 24 - Ibre channel San

DS300f G2 Series User Manual 6featurescontroller moDule featureSdrive suPPort• 3.5-inch and 2.5-inch form factor• Hard disk drives (HDDs) and Solid

Página 25 - AnAgeMent PAth

DS300f G2 Series User Manual 1146. Click the Submit button.The new trunk is added to the list.Specify the trunk when your create a portal. See "

Página 26

DS300f G2 Series User Manual 115Information includes:• SessionID–IDnumberofthesession• Status–Activeorinactive• TargetAlias• Initiato

Página 27

DS300f G2 Series User Manual 116vIewInG a lISt of IScSI chaPSTo view a list of iSCSI CHAPs:1. Click the Device tab.2. Click the iSCSI Management ic

Página 28

DS300f G2 Series User Manual 117PInGInG a hoSt or Server on the IScSI networkThisfunctionenablesyoutopingothernetworknodesthroughanyoneof

Página 29

DS300f G2 Series User Manual 118This chapter covers the following topics:• "Managing the Subsystem (CLU)" on page 122• "Managing the

Página 30 - Management Port

DS300f G2 Series User Manual 119InItIal ConneCtIonMaking an initial connection includes the following functions:• "Making a Serial Connection&q

Página 31

DS300f G2 Series User Manual 120makInG a SSh connectIonA Secure Shell (SSH) connection requires a network connection between the Host PC and the Mana

Página 32

DS300f G2 Series User Manual 121Quick Setup–Asequenceoffourstepstosetupsystemdateandtime,Managementport,andRAIDconguration.See &q

Página 33

DS300f G2 Series User Manual 122ManaGInG the subsysteM (Clu)Subsystem Management includes the following functions:• "Making Subsystem Settings

Página 34

DS300f G2 Series User Manual 123releAsing the lock1. From the Main Menu, highlight Subsystem Management and press Enter.2. Highlight Lock Managemen

Página 35

DS300f G2 Series User Manual 7bAckground Activities• Media Patrol• Background Synchronization• Foreground Initialization• Rebuild• Redundancy Ch

Página 36 - ConneCtInG the power

DS300f G2 Series User Manual 124ManaGInG the raId Controllers (Clu)RAID controller management includes the following functions:• "Viewing Contr

Página 37

DS300f G2 Series User Manual 125• HighlightHost Cache FlushingandpressthespacebartotogglebetweenEnableandDisable.Formoreinformation,se

Página 38

DS300f G2 Series User Manual 126ManaGInG the enClosure (Clu)Enclosure Management includes the following functions:• "Viewing the Enclosures Sum

Página 39

DS300f G2 Series User Manual 127vIewInG fru vPD InformatIon (clu)FRU VPD refers to Vital Product Data (VPD) information about Field Replaceable Units

Página 40 - LED Description

DS300f G2 Series User Manual 1284. Highlight Voltage Sensors and press Enter.If any voltage is outside the Healthy Threshold values, there is a volt

Página 41 - Chapter 3: setup

DS300f G2 Series User Manual 129vIewInG encloSure toPoloGy (clu)This feature displays the connection topology of the ASUS DS300f G2 subsystem. Topolo

Página 42

DS300f G2 Series User Manual 130• HighlightDMA ModeandpressthespacebartotogglethroughUDMA0to6andMDMA0to2.For SAS drives:•Highlight

Página 43 - IPv4 and press Enter

DS300f G2 Series User Manual 131on page 135. After rebuilding, the drive shows Stale. Run Clear Stale then run Clear PFA.If the physical drive with a

Página 44

DS300f G2 Series User Manual 132ManaGInG dIsk arrays (Clu)Disk Array Management includes the following functions:• Viewing a List of Disk Arrays (pa

Página 45

DS300f G2 Series User Manual 133• File Server• Video Stream• Transaction Data• Transaction Log• Other7. Press Control-A to save your settings a

Página 46 - Enter to enable IPv6

DS300f G2 Series User Manual 8suPPorted oPerAting systeMsOperating systems run on the Host PC, from which you monitor and manage the ASUS DS300f G2 s

Página 47 - IPMask: 255.0.0.0

DS300f G2 Series User Manual 134Step 3 – SummaryReview logical drives you are about to create for your new array. Then do one of the following action

Página 48 - Figure 3 - 1: CLU main menu

DS300f G2 Series User Manual 135accePtInG an IncomPlete array (clu)This condition is the result of a missing physical drive. See “Incomplete Array” o

Página 49

DS300f G2 Series User Manual 136runnInG PDm on a DISk array (clu)Predictive Data Migration (PDM) migrates data from the suspect physical drive to a s

Página 50 - ManaGeMent

DS300f G2 Series User Manual 137ManaGInG spare drIves (Clu)Spare Drive Management includes the following functions:• "Viewing a list of Spare D

Página 51

DS300f G2 Series User Manual 138runnInG SPare check (clu)To run Spare Check:1. From the Main Menu, highlight Spare Drive Management and press Enter.

Página 52

DS300f G2 Series User Manual 1396. Highlight the following parameters and press the spacebar to toggle though the available choices:• Stripe size

Página 53 - Next button to continue

DS300f G2 Series User Manual 140makInG loGIcal DrIve SettInGS (clu)To make Logical Drive settings:1. From the Main Menu, highlight Logical Drive Man

Página 54 - Add button to continue

DS300f G2 Series User Manual 14110. Highlight Save Logical Drive and press Enter.The screen returns to Disk Array Migration Logical Drives.At this po

Página 55 - Submit button

DS300f G2 Series User Manual 1429. Highlight Start and press enter to begin the cloning process.10. Press any key to continue.11. PressYtoconrm

Página 56

DS300f G2 Series User Manual 1435. Highlight each of the following and press the backspace key to erase the current value, then type the new value.•

Página 57 - PeruSInG the Interface

DS300f G2 Series User Manual 9General speCIfICatIonsPower suPPlies• Hot swap and redundant with PFC, 100-240 Vac auto-ranging, 50 -60 Hz, N+1 design

Página 58

DS300f G2 Series User Manual 144vIewInG fIbre channel loGGeD-In DevIceS (clu)To view a list of logged-in devices:1. From the Main Menu, highlight Fi

Página 59 - ManaGInG subsysteMs

DS300f G2 Series User Manual 145vIewInG fIbre channel Port StatIStIcS (clu)To view port statistics:1. From the Main Menu, highlight Fibre Channel Ma

Página 60 - IewInG SubSyStem InformatIon

DS300f G2 Series User Manual 146ManaGInG IsCsI ConneCtIons (Clu)• "Viewing iSCSI Target Information (CLU)" on page 147• "Making iSCS

Página 61

DS300f G2 Series User Manual 147vIewInG IScSI tarGet InformatIon (clu)To view information for an iSCSI target:1. From the Main Menu, highlight iSCSI

Página 62 - SavInG a ServIce rePort

DS300f G2 Series User Manual 148vIewInG a lISt of IScSI PortS (clu)An iSCSI port is the physical iSCSI connection on the ASUS DS300f G2. There are fo

Página 63

DS300f G2 Series User Manual 149vIewInG IScSI Portal InformatIon (clu)To view information for an iSCSI target port:1. From the Main Menu, highlight

Página 64 - ManaGInG raId Controllers

DS300f G2 Series User Manual 150• VlanTag–VLANtagnumber(1to4094)forportalsassociatedwithaVLAN• TrunkId–TrunkIDnumber(1to8)for

Página 65

DS300f G2 Series User Manual 151vIewInG IScSI SeSSIon InformatIon (clu)To view a list of iSCSI sessions:1. From the Main Menu, highlight iSCSI Manag

Página 66 - IewInG controller StatIStIcS

DS300f G2 Series User Manual 152vIewInG a lISt of IScSI chaPS (clu)Challenge Handshake Authentication Protocol (CHAP) is an authentication mechanism

Página 67

DS300f G2 Series User Manual 153• HighlightPing Through Controller IDandchooseacontroller(1or2)• HighlightPing Through Port IDandchoose

Página 68 - Aking schedule chAnges

DS300f G2 Series User Manual 10sAfety And environMentAleMi / rfi stAteMentsbsMiceWarning: This is a class A product. In a domestic environment this p

Página 69 - ManaGInG enClosures

DS300f G2 Series User Manual 154ManaGInG baCkGround aCtIvIty (Clu)Background activity refers to any of several functions that take place in the backg

Página 70 - IewInG encloSure toPoloGy

DS300f G2 Series User Manual 155workInG wIth the event vIewer (Clu)Working with the Event Viewer includes the following functions:• "Viewing Ru

Página 71 - IewInG encloSure InformatIon

DS300f G2 Series User Manual 156workInG wIth lun MappInG (Clu)LUN Mapping includes the following functions:• "Enabling LUN Mapping (CLU)"

Página 72 - IewInG voltaGe SenSor StatuS

DS300f G2 Series User Manual 157DeletInG an InItIator (clu)CautionIf you delete an initiator, you delete the LUN map associated with that initiator.

Página 73 - ManaGInG ups unIts

DS300f G2 Series User Manual 158MAPPing A lun to An iscsi initiAtor or tArgetTo map a LUN to an iSCSI initiator or target:1. From the Main Menu, hig

Página 74 - ManaGInG network ConneCtIons

DS300f G2 Series User Manual 159ManaGInG ups unIts (Clu)Uninterruptible Power Supply (UPS) Management includes the following functions:• "Viewi

Página 75 - ManaGInG users

DS300f G2 Series User Manual 160vIewInG uPS InformatIon (clu)ToviewinformationaboutaspecicUPS unit:1. From the Main Menu, highlight Additiona

Página 76

DS300f G2 Series User Manual 1615. Highlight Privilege and press the space bar to toggle though the options.See the Table on the next page.6. Press

Página 77 - ImPortInG a uSer DatabaSe

DS300f G2 Series User Manual 162chanGInG your own PaSSworD (clu)Each user can change their own password.To change your password:1. From the Main Men

Página 78

DS300f G2 Series User Manual 163workInG wIth software ManaGeMent (Clu)Software Management includes the following functions:• "Making Email Sett

Página 79

DS300f G2 Series User Manual 11wArrAnty And suPPortwArrAnty• Three year complete system limited warranty• Battery Backup Unit has a one year limite

Página 80

DS300f G2 Series User Manual 164makInG telnet SettInGS (clu)By default, Telnet service is set to Manual and its normal status is Stopped.To make Teln

Página 81 - MAking MediA PAtrol settings

DS300f G2 Series User Manual 165Adding A trAP sinkTo add a trap sink:1. From the Main Menu, highlight Additional Info and Management and press Enter

Página 82 - IGratIon

DS300f G2 Series User Manual 1666. Typetherecipient’sIPaddressintotheeldprovided.7. Highlight Message Event Severity Filter and press the

Página 83 - SynchronIzatIon

DS300f G2 Series User Manual 167ClearInG statIstICs (Clu)This function clears the statistical counts for the RAID controller, Fibre Channel ports, iS

Página 84 - ManaGInG storaGe servICes

DS300f G2 Series User Manual 168shuttInG down the subsysteM (Clu)There are two methods for shutting down the subsystem. Choose one of the following p

Página 85

DS300f G2 Series User Manual 1695. Highlight Submit and press Enter.A warning message appears.6. Press Y to continue.7. The subsystem will then tu

Página 86 - MAking telnet settings

DS300f G2 Series User Manual 170StartInG uP the aSuS DS300f G2 – SerIal connectIonImportantIfyouhaveaJBODExpansion,alwayspowerontheJBODsub

Página 87 - Adding An snMP trAP sink

DS300f G2 Series User Manual 171reStartInG aSuS DS300f G2 – SSh connectIonTo restart the RAID subsystem:1. From the Main Menu, highlight Additional

Página 88

DS300f G2 Series User Manual 172Chapter 6: MaIntenanCeThis chapter covers the following topics:• "Updating the Subsystem Firmware" on page

Página 89 - Aking netsend settings

DS300f G2 Series User Manual 1736. Click the Next button.ThenextscreenshowstheFlashImage(rmwareimagele)VersionNumberandBuildDate.7.

Página 90 - SavInG runtIme eventS

DS300f G2 Series User Manual 12Chapter 2: hardware InstallatIonThis chapter covers the following topics:• "Unpacking the ASUS DS300f G2" o

Página 91 - MonItorInG perforManCe

DS300f G2 Series User Manual 174 AutoMAtic restArtIf you chose the Disruptive Flash Method, the RAID subsystem and JBOD expansion units automatically

Página 92

DS300f G2 Series User Manual 175restart. No reconnect is required. fAiled uPdAteIfthermwareupdatefails,thecontrollerstatusLEDdisplaysred.

Página 93 - ManaGInG physICal drIves

DS300f G2 Series User Manual 176reStartInG a SubSyStemThis function shuts down the subsystem and then restarts it.ImportantDo NOT turn off the power

Página 94

DS300f G2 Series User Manual 177InStallInG a new Power SuPPlytTo install the power supply:1. Carefully slide the power supply into the enclosure.2.

Página 95

DS300f G2 Series User Manual 178replaCInG a CoolInG unItA failed Cooling Unit on the ASUS DS300f G2 or DS300j G2 can be hot swapped if the other cool

Página 96

DS300f G2 Series User Manual 179Figure 6 - 6: Number 2 Cooling Unit with Cache Backup Battery (BBU) LED indicating battery failurereplaCInG a CaChe b

Página 97 - ManaGInG dIsk arrays

DS300f G2 Series User Manual 180Figure 6 - 4: RAID controller release handle and pull outreplaCInG a raId Controller – dual ControllersThe RAID contr

Página 98

DS300f G2 Series User Manual 181InStallInG the new controllerTo install the new RAID controller:1. Carefully slide the RAID controller into the encl

Página 99 - DeletInG a DISk array

DS300f G2 Series User Manual 182removInG the olD controllerTo remove the RAID controller:1. Shutdown the ASUS DS300f G2. 2. Disconnect all attached

Página 100

DS300f G2 Series User Manual 183Chapter 7: teChnoloGy baCkGroundThis chapter covers the following topics:• "Disk Arrays" on page 183• &qu

Página 101 - PerforMing A MAnuAl rebuild

DS300f G2 Series User Manual 13unpaCkInG the asus ds300f G2The ASUS DS300f G2 box contains the following items:• ASUSDS300fG2Unit(PTVR2K)• Quic

Página 102 - ManaGInG loGICal drIves

DS300f G2 Series User Manual 184PDmPredictive Data Migration (PDM) is the migration of data from the suspect phyical drive to a spare drive, similar

Página 103

DS300f G2 Series User Manual 185RAID 0 logical drives on ASUS DS300f G2 consist of one or more physical drives.Advantages Disadvantages•Implementsa

Página 104 - DeletInG a loGIcal DrIve

DS300f G2 Series User Manual 186• Imaging applications • Database servers • GeneralleserverrAid 3 - block striPe And dedicAted PArityRAID 3 orga

Página 105 - InItIalIzInG a loGIcal DrIve

DS300f G2 Series User Manual 187Mirror + Stripe combines both of the RAID 1 and RAID 0 logical drive types. RAID 10 can increase performance by readi

Página 106 - MigrAting A logicAl drive

DS300f G2 Series User Manual 188theRAID50logicaldrivegoingofine.Component Minimum MaximumNumberofAxles 2 16PhysicalDrivesperAxle 3 32Phys

Página 107 - ManaGInG spare drIves

DS300f G2 Series User Manual 189RAID 60 Logical DriveNo. of Drives No. of Axles Drives per AxleNo. of DrivesNo. of Axles Drives per Axle8 2 4,4 17 2

Página 108 - DeletInG a SPare DrIve

DS300f G2 Series User Manual 190RAID 53physicaldrivesminimum,32maximum.RAID0musthavelessthan16physicaldrives.Ifexistingphysicaldri

Página 109

DS300f G2 Series User Manual 191RAID 608physicaldrivesminimum,32peraxlemaximum.Ifexistingphysicaldriveshavenounusedspace,add1ormor

Página 110 - ManaGInG InItIators

DS300f G2 Series User Manual 192StrIPe SIzeStripe Size, also called “Stripe Block Size,” refers to the size of the data blocks written to, and read f

Página 111 - ManaGInG luns

DS300f G2 Series User Manual 193spare drIvesSpare drive technology includes:• "Denition"onpage193• "Options" on page 193•

Página 112 - DItInG a lun maP

ContentsChapter 1: IntroduCtIon 1about thIs Manual 2asus ds300f G2 overvIew 3Performance 3GreenraID 3ServIce anD SuPPort 3new featureS In the aS

Página 113 - DeletInG a lun maP

DS300f G2 Series User Manual 14MountInG asus ds300f G2 In a raCkCautions• Do not populate any unit with hard drives until it has been securely insta

Página 114 - IewInG fc Port StatIStIcS

DS300f G2 Series User Manual 194data from the revertible spare drive.See the example on the following pages.exAMPleFollowing is an example to explain

Página 115 - ManaGInG IsCsI ConneCtIons

DS300f G2 Series User Manual 195• Set the redundancy type to Active-Active.See "Making Subsystem Settings (CLU)" on page <?>.• Enab

Página 116

DS300f G2 Series User Manual 196loss.AdvAnced bAttery flAsh bAckuP Thisfeatureusespowerfromthe BBUtosavethewrite cacheusedfortheRAIDc

Página 117 - DDInG IScSI PortalS

DS300f G2 Series User Manual 197IsCsI ManaGeMentiSCSI management uses the following terms:• "iSCSI on a VLAN" on page 197• "Initiato

Página 118 - DeletInG IScSI PortalS

DS300f G2 Series User Manual 198InItIatorAn initiator functions as the client, in this case, your host PC or server. The initiator makes requests to

Página 119 - DDInG IScSI trunkS

DS300f G2 Series User Manual 199PortA port is the physical point of connection between the ASUS DS300f G2 and the iSCSI network. There are four ports

Página 120 - DeletInG IScSI trunkS

DS300f G2 Series User Manual 200Internet protoColsASUS DS300f G2 supports the IPv4 and IPv6 protocols.Protocol Addresses ExampleIPv4 32-bits 4.3x10

Página 121 - DeletInG an IScSI SeSSIon

DS300f G2 Series User Manual 201Chapter 8: troubleshootInGThis chapter contains the following topics:• ASUS DS300f G2 is Beeping (below)• LEDs Disp

Página 122 - DeletInG IScSI chaPS

DS300f G2 Series User Manual 202leds dIsplay aMber or redLEDs are used on ASUS DS300f G2’s:• Front Panel LEDs (page 202)• Drive Carrier LEDs (page

Página 123

DS300f G2 Series User Manual 203DrIve carrIer leDSTheASUSDS300fG2spinsupthediskdrivessequentiallytoequalizepowerdrawduringstart-up.Af

Página 124 - <?>

DS300f G2 Series User Manual 15Figure 2 - 3: Rail ends attach to the outside of each post1. Place the ASUS DS300f G2 subsystem onto the rails.•Atl

Página 125 - InItIal ConneCtIon

DS300f G2 Series User Manual 204Figure 8 - 4: ASUS DS300f G2 controller LEDsFigure 8 - 5: JBOD controller LEDs Undernormalconditions,thepowersu

Página 126 - Figure 5 - 3: CLU main menu

DS300f G2 Series User Manual 205LEDDescriptionFC ports(oneLEDaboveeachport)Green Amber Statusdark darkWake-upfailure(deadboard)off on POSTfai

Página 127

DS300f G2 Series User Manual 206checkInG comPonent InStallatIonTocheckacomponent’sinstallation,removethecomponent,thenreinstallthecomponen

Página 128 - ManaGInG the subsysteM (Clu)

DS300f G2 Series User Manual 207vIewInG nvram eventSThisscreendisplaysalistofandinformationabout63mostimportanteventsovermultiplesubsy

Página 129

DS300f G2 Series User Manual 208asus storaGe ManaGeMent reports a probleMASUS Storage Management reportstheseconditionsintheheaderandallfour

Página 130

DS300f G2 Series User Manual 209usb support reports a probleMThis procedure requiresaUSBashdevice:• Formatted to FAT 32• At least 50 MB of fre

Página 131

DS300f G2 Series User Manual 210overheatInGOverheating is a potentially serious condition because the excessively high temperatures can lead to physi

Página 132 - ManaGInG the enClosure (Clu)

DS300f G2 Series User Manual 211raId Controller probleMsRAID controller problems include:• "Maintenance Mode" on page 211• "Finding

Página 133

DS300f G2 Series User Manual 212seriAl connectionTo clear maintenance mode using a serial connection:1. Changeyourterminalemulationprogramsetti

Página 134 - Attery notes

DS300f G2 Series User Manual 213physICal drIve probleMsPhysicaldrivesarethefoundationofdatastorage.Aphysicaldriveproblemcanaffectyoure

Página 135

DS300f G2 Series User Manual 16InstallInG physICal drIvesIf your ASUS DS300f G2 subsystem shipped with the drives installed at the factory, you can s

Página 136 - SettInG an alIaS (clu)

DS300f G2 Series User Manual 214• Storage tabDisk Array and Logical Drive are marked Critical with a yellow ! icon.RAID 6 and 60 logical drives ar

Página 137

DS300f G2 Series User Manual 215rebuIlDInG a DISk arrayWhenyourebuildadiskarray,youareactuallyrebuildingthedataononephysicaldrive.• W

Página 138 - ManaGInG dIsk arrays (Clu)

DS300f G2 Series User Manual 216ConneCtIon probleMsConnection problems include:• "Serial Connections" on page 216• "Network Connecti

Página 139

DS300f G2 Series User Manual 217fIbre channel connectIonSWhenthereisaconnectionfailure,useASUSStorageManagementtoverifythatASUSDS300fG

Página 140 - DeletInG a DISk array (clu)

DS300f G2 Series User Manual 218power CyClInG the subsysteMTo power cycle a RAID subsystem means to:• Shut down• Turn off the power• Turn on the p

Página 141

DS300f G2 Series User Manual 219Reported Event Corrective ActionBatteryBattery is insertedNo action is required.Battery charging has failedReplace th

Página 142

DS300f G2 Series User Manual 220Controller was placed on reset during Fail Over processingNo action is required.Partner Controller was placed on rese

Página 143 - ManaGInG spare drIves (Clu)

DS300f G2 Series User Manual 221Host interface controller has received a “clear task set” command.No action is required.Host interface controller has

Página 144 - ManaGInG loGICal drIves (Clu)

DS300f G2 Series User Manual 222Online capacity expansion has stoppedIf this action was not intentional, check the logical drive’s status.Online capa

Página 145

DS300f G2 Series User Manual 223PSU fan or blower is insertedNo action is required.PSU fan or blower is functioning normallyPSU fan or blower is NOT

Página 146

DS300f G2 Series User Manual 17InStallInG your DrIveSThe drive carrier accommodates 2.5-inch and 3.5-inch drives, with or without a SAS-to-SATA adapt

Página 147

DS300f G2 Series User Manual 224Synchronization is completedNo action is required.Synchronization is pausedResume synchronization when ready.Synchron

Página 148 - Aking MAnuAl settings

DS300f G2 Series User Manual 225Chapter 9: supportThis chapter contains the following topics:• "Frequently Asked Questions" on page 225•

Página 149

DS300f G2 Series User Manual 226Can ASUS DS300f G2 run using just one power supply? The ASUS DS300f G2 must use at least two power supplies. ASUS D

Página 150 - IewInG SfP InformatIon (clu)

DS300f G2 Series User Manual 227creatInG a DISk array or loGIcal DrIveWhy can’t I see all RAID Levels in RAID Level drop-down menu?The selection of R

Página 151 - ProPerty definitions

DS300f G2 Series User Manual 228ContaCtInG teChnICal supportASUS Storage Technical Support provides several support options for ASUS Storage users to

Página 152

DS300f G2 Series User Manual 229norwAy itfTechnical Support (E-Support): https://support.ASUS Storage.comWeb site: http://www.ASUS Storage.com//belgu

Página 153

DS300f G2 Series User Manual 230liMited wArrAntyASUS Storage Technology, Inc. (“ASUS Storage”) warrants that this product, from the time of the deliv

Página 154

DS300f G2 Series User Manual 231• Daytime phone number• Description of the problem• Copy of the original purchase invoiceThe technician helps you

Página 155 - DDInG IScSI PortalS (clu)

DS300f G2 Series User Manual 232appendIx a: useful InforMatIonThe appendix covers the following topics:• SNMP MIB Files (below)• Adding a Second RA

Página 156 - DeletInG IScSI PortalS (clu)

DS300f G2 Series User Manual 233addInG a seCond raId ControllerIfyourASUSDS300fG2subsystemshippedwithoneRAIDcontroller,youcanaddasecon

Página 157

DS300f G2 Series User Manual 18MakInG ManaGeMent and data ConneCtIonsExamplesofASUSDS300fG2congurationsinclude:• "Fibre Channel SAN"

Página 158 - DeletInG IScSI chaPS (clu)

DS300f G2 Series User Manual 234• LUNAfnity–IfyouchooseActive-Activeredundancy.See“MakingControllerSettings”onpage86orpage216.NoteT

Página 159 - DeletInG IScSI trunkS (clu)

DS300f G2 Series User Manual 235appendIx b: MultIpathInG on wIndowsThe appendix covers the following topics:• Before You Begin• Installing PerfectP

Página 160

DS300f G2 Series User Manual 236InstallInG perfeCtpathTo install the PerfectPath software:1. DownloadthePerfectPathinstallerlefromASUSStorag

Página 161 - Event Severity Levels

DS300f G2 Series User Manual 237DevIce manaGerToverifyPerfectPathinstallationintheDeviceManager:1. FromtheWindowsdesktop,right-clickthe

Página 162 - DDInG an InItIator (clu)

DS300f G2 Series User Manual 238MonItorInG your luns and pathsMonitoringyourLUNsandPathsincludesthesefunctions:• ViewingLUNProperties• Vi

Página 163 - DeletInG an InItIator (clu)

DS300f G2 Series User Manual 239See also:•“ViewingPathPerformanceStatistics”• “LoadBalancePolicy”vIewInG Path Performance StatIStIcSToview

Página 164 - DeletInG a lun maP (clu)

DS300f G2 Series User Manual 240features and settInGsFeatures and Settings include the following functions:• AutomaticLoadBalancingforFailoverP

Página 165 - ManaGInG ups unIts (Clu)

DS300f G2 Series User Manual 2412. ClicktheoptionbuttonforoneoftheLoadPolicies.• FailoverPolicy• RoundRobinPolicy• RoundRobinwithS

Página 166 - ManaGInG users (Clu)

DS300f G2 Series User Manual 2422. ClickthearrowsortypeanewvalueinthePDORemovePeriodeldtochangetheinterval.120secondsistheASUS

Página 167 - User Privileges

DS300f G2 Series User Manual 243vIewInG SyStem InformatIonToviewSysteminformationandsettings,dooneofthefollowingactions:• FromtheSystem

Página 168 - DeletInG a uSer (clu)

DS300f G2 Series User Manual 19fc sAn dAtA PAthTo establish the data path:1. Connect FC cables between at least one FC data port on each RAID contro

Página 169

DS300f G2 Series User Manual 244updatInG perfeCtpathToupdateyourPerfectPathsoftwaretothelatestversion:1. DownloadthenewPerfectPathinstal

Página 170

DS300f G2 Series User Manual 245reMovInG perfeCtpathPreferreD methoDThisprocedureusestheuninstallerincludedwithPerfectPath.ToremovethePerfe

Página 171

DS300f G2 Series User Manual 246appendIx C: MultIpathInG on lInuxThe appendix covers the following topics:• Before You Begin • Task1:MeetingPack

Página 172

DS300f G2 Series User Manual 247task 1: MeetInG paCkaGe requIreMentsThelatest device mapperand multipath packagesmustbe loadedonto yourLi

Página 173 - ClearInG statIstICs (Clu)

DS300f G2 Series User Manual 248verIfyInG PackaGeS – SuSeToverifythattherequiredpackagesareinstalledonthehost,dothefollowingactions:1.

Página 174

DS300f G2 Series User Manual 249devices { device {vendor “ASUS Storage” product “DS300fG2” path_grouping_policy multibusgetuid_callout “/sbin/sc

Página 175 - Enter to open the CLU

DS300f G2 Series User Manual 250verIfyInG the moDuleS are loaDeDToverifythattheDM-MPmodulesareloaded:1. Openaterminalwindow.2. Verifytha

Página 176

DS300f G2 Series User Manual 251task 5: settInG-up aluaASUSDS300fG2supportsAsymmetricLogicalUnitAccess(ALUA)onthelatestLinuxdistribution

Página 177 - SIlencInG the buzzer

DS300f G2 Series User Manual 252#>uname-a2. Do one of the following actions:•Removethecurrentlyinstalledmultipathtool.rpm-evmultipath-t

Página 178 - Chapter 6: MaIntenanCe

DS300f G2 Series User Manual 2531. CopytheASUSStorage-suppliedmultipath.confletothe/etcdirectory.#>cpmultipath.conf.alua-sles11sp1/e

Página 179 - PDatInG wIth the clu

DS300f G2 Series User Manual 20fIbre channel DaSImportantFor a list of supported HBAs, switches, and SFP transceivers, download the latest compatibil

Página 180 - PDatInG wIth uSb SuPPort

DS300f G2 Series User Manual 254RHEL-5.4 package scsi_dh_alua_ASUSDS300fG2Dual-1-1.src.rpmALUA multipath.conf-ASUSDS300fG2-alua-rhel5-4HowtoC

Página 181 - Ailed uPdAte

DS300f G2 Series User Manual 255WithaFibreChannelswitch,adev_loss_tmovaluesettoosmallcanresultinlossofthepathduringfailover/failba

Página 183

DS300f G2 Series User Manual 21fIbre channel wIth JboD exPanSIonJBOD expansion requires at least one SFF-8088 4X to SFF-8088 4X external SAS cable fo

Página 184

DS300f G2 Series User Manual 22fIbre channel San – no SInGle PoInt of faIlure An FC SAN with no single point of failure (NSPF) requires:• An FC HBA

Página 185

DS300f G2 Series User Manual 23fc sAn nsPf MAnAgeMent PAthTo establish the management path:1. Connect an Ethernet cable between the Management port

Página 186 - Controllers

SlP ServIce 79webServer ServIce 79telnet ServIce 80SSh ServIce 80SnmP ServIce 81netSenD ServIce 82workInG wIth the event vIewer 84vIewI

Página 187 - Controller

DS300f G2 Series User Manual 24IScSI StoraGe area network (San)ImportantFor a list of supported HBA NICs and switches, download the latest compatibil

Página 188 - InStallInG the new controller

DS300f G2 Series User Manual 25iscsi sAn dAtA PAthEach ASUS DS300f G2 controller has four (4) RJ45 iSCSI data port connectors. See "Figure 2 - 1

Página 189 - Isk arrays

DS300f G2 Series User Manual 26Figure 2 - 17: iSCSI SAN management connectionsMAnAgeMent PAthEach ASUS DS300f G2 controller has one (1) Ethernet RJ45

Página 190

DS300f G2 Series User Manual 27IScSI DIrect attacheD StoraGe (DaS)ImportantFor a list of supported HBAs and switches, download the latest compatibili

Página 192

DS300f G2 Series User Manual 29MakInG serIal Cable ConneCtIonsSerial communication enables the terminal emulation application on your host PC or serv

Página 193

DS300f G2 Series User Manual 30ConneCtInG the powerTo power on the ASUS DS300f G2 and any connected DS300j G2 system, follow these steps:1. Connect

Página 194

DS300f G2 Series User Manual 31Figure 2 - 22: Right side of the DS300f G2 front LED displayFigure 2 - 23: Left side of the front of the ASUS DS300f G

Página 196

DS300f G2 Series User Manual 33controller led behAviorWhenboot-upisnishedandtheASUSDS300fG2subsystemisfunctioningnormally,theControlle

Página 197

locatInG an encloSure (clu) 128vIewInG encloSure toPoloGy (clu) 129 physICal drIve ManaGeMent (Clu) 129vIewInG a lISt of PhySIcal DrIveS (clu) 12

Página 198 - PartItIon anD format

DS300f G2 Series User Manual 34LED DescriptionFC ports(oneLEDaboveeachport)Green Amber Statusdark darkWake-upfailure(deadboard)off on POSTfai

Página 199 - DefInItIon

DS300f G2 Series User Manual 35Chapter 3: setupThis chapter covers the following topics:• "Setting-up the Serial Connection" on page 35•

Página 200 - AnuAl trAnsition

DS300f G2 Series User Manual 36about Ip addresses• ASUS DS300f G2 Default IP Addresses (page 36)• Choosing DHCP or a Static IP Address (page 36)•

Página 201 - AdAPtive writebAck cAche

DS300f G2 Series User Manual 37acceSSInG the mac aDDreSS In the cluTo access the MAC address in the CLU:1. At the CLI command prompt, type menu and

Página 202 - Power SavInG

DS300f G2 Series User Manual 38vIrtual manaGement Port SettInGSMAking virtuAl MAnAgeMent Port settings – AutoMAticAllyAutomatic settings require a DH

Página 203 - ScSI on a vlan

DS300f G2 Series User Manual 39Example:administrator@cli> net -a mod -f ipv6 -s “primaryip=2001:0db8:85a3:0000:0000:8a2e:0370:7334, primaryipmask=

Página 204

DS300f G2 Series User Manual 40MAking MAintenAnce Mode settings – MAnuAlly under iPv4You make these settings for one controller at a time.To make mai

Página 205

DS300f G2 Series User Manual 413. To verify the settings, at the command prompt, type net -a list -m and press Enter. The following information disp

Página 206 - Internet protoCols

DS300f G2 Series User Manual 42acceSSInG the clu quIck SetuP menuTo access the Quick Setup menu in the command line utility:1. At the administrator@

Página 207 - Chapter 8: troubleshootInG

DS300f G2 Series User Manual 43viewing virtuAl MAnAgeMent Port settingsTo view the current IP address and network settings when using DHCP:1. Press

Página 208 - DarkmeanstheLEDisoff

SIlencInG the buzzer 171Chapter 6: MaIntenanCe 172updatInG the subsysteM fIrMware 172uPDatInG wIth aSuS StoraGe manaGement 172uPDatInG wIth the cl

Página 209 - DrIve carrIer leDS

DS300f G2 Series User Manual 44MAking MAintenAnce Mode settings – MAnuAlly under iPv6To make maintenance mode IPv6 manual settings:1. From the CLU M

Página 210

DS300f G2 Series User Manual 45ImportantASUS Storage recommends that you change the Administrator’s default password immediately after setup is compl

Página 211 - FC ports

DS300f G2 Series User Manual 46wIzarD - automatIc confIGuratIonWhen you choose the Automatic option, the following parameters appear on the screen:•

Página 212 - Clu reports a probleM

DS300f G2 Series User Manual 47wIzarD - aDvanceD confIGuratIonNoteForanexplanationoftheparametersundertheAdvancedoption,see"Chapter7

Página 213 - IewInG nvram eventS

DS300f G2 Series User Manual 48steP 2 – logicAl drive creAtion1. Enter your information and choose your options.•Enteralogicaldrivealiasinthe

Página 214 - StoraGe tab

DS300f G2 Series User Manual 49steP 4 – suMMAryTheSummaryscreenliststhediskarrays,logicaldrives,andsparedrivesthatyouspecied.If you ac

Página 215

DS300f G2 Series User Manual 50Chapter 4: ManaGe wIth asus storaGe ManaGeMentThis chapter contains the following topics:• "Logging into ASUS St

Página 216 - Power SuPPlIeS

DS300f G2 Series User Manual 51chooSInG the DISPlay lanGuaGeASUS Storage Management displays in multiple languages. You choose the display language w

Página 217 - internAl checks

DS300f G2 Series User Manual 52• Subsystemsettings,clearingstatistics,NTP,andcontrollerlock• Usermanagement,includingLDAPandrolemappin

Página 218

DS300f G2 Series User Manual 53vIewInG the storaGe networkTo view the other subsystems on your StorageNetwork,clicktheDiscovery tab at the left e

Página 219 - Device tab

vIewInG Path Performance StatIStIcS 239vIewInG eventS 239clearInG Path StatIStIcS 239features and settInGs 240automatIc loaD balancInG for faIl

Página 220 - And 60 logicAl drives

DS300f G2 Series User Manual 54vIewInG SubSyStem InformatIonTo view subsysteminformation,clicktheAdministration tab.The list of subsystems and ho

Página 221 - IncomPlete array

DS300f G2 Series User Manual 55releAsing A lock set by Another userTo release somebody else’s lock:1. Click the Administration tab.2. Click the Sub

Página 222 - ConneCtIon probleMs

DS300f G2 Series User Manual 56SavInG a ServIce rePortA Service Reportis adetailed reportcoveringthecongurationandstatusofallcomponents

Página 223 - Ibre channel connectIonS

DS300f G2 Series User Manual 57ImPortInG a confIGuratIon ScrIPtYou can write a CLI congurationscripttoautomaticallycongureyourASUSDS300fG2

Página 224

DS300f G2 Series User Manual 58ShuttInG Down the SubSyStemThis function shuts down the RAID subsystem without restarting it.To shutdown the subsystem

Página 225

DS300f G2 Series User Manual 594. Click the Advanced Information tab.Advanced controller information includes:•Slot1MemoryType• Slot2MemoryT

Página 226

DS300f G2 Series User Manual 60vIewInG controller StatIStIcSTo view controller statistics:1. Click the Device tab.2. Click the Component List icon.

Página 227

DS300f G2 Series User Manual 61uPDatInG fIrmware on a raID SubSyStemUsethisfunctiontoash(update)thermwareontheASUSDS300fG2.Download the

Página 228

DS300f G2 Series User Manual 62vIewInG battery InformatIonBatteriesmaintainpowertothecontrollercacheintheeventofapowerfailure,thusprot

Página 229

DS300f G2 Series User Manual 63buzzer SettInGSTo make buzzer settings:1. Click the Device tab.2. Click the Component List icon.3. Click the Buzzer

Página 230

DS300f G2 Series User Manual 1Chapter 1: IntroduCtIonThis chapter covers the following topics:• "About This Manual" on page 2• "ASUS

Página 231 - Chapter 9: support

DS300f G2 Series User Manual 64vIewInG encloSure toPoloGyThisfeaturedisplaystheconnectiontopologyoftheASUSDS300fG2subsystem.Topologyrefe

Página 232 - Super User can create a User

DS300f G2 Series User Manual 65vIewInG the encloSureS SummaryEnclosureManagementincludesinformation,status,settingsandlocation.ToaccessEncl

Página 233

DS300f G2 Series User Manual 66vIewInG fru vPD InformatIonFRU VPD refers to Vital Product Data (VPD) information about Field Replaceable Units (FRU)

Página 234 - ContaCtInG teChnICal support

DS300f G2 Series User Manual 67ManaGInG ups unItsUninterruptible Power Supply (UPS) Management includes the following functions:• "Viewing a Li

Página 235

DS300f G2 Series User Manual 68vIewInG uPS InformatIonToviewinformationaboutaspecicUPS unit:1. Click the Device tab.2. Click the UPS icon.3.

Página 236

DS300f G2 Series User Manual 69makInG maIntenance moDe SettInGSEach controller has its own IP addresses for access when the controller goes into main

Página 237

DS300f G2 Series User Manual 70creatInG a uSerThis action requires Administrator or SuperUser privileges.To create a user:1. Click the Administrati

Página 238

DS300f G2 Series User Manual 71DeletInG a uSerThis action requires Administrator or SuperUser privileges.NoteYou cannot delete the Administrator.To

Página 239 - Component Listicon

DS300f G2 Series User Manual 72exPortInG a uSer DatabaSeYoucansavetheuserinformationandsettingsfromoneASUSDS300fG2RAIDsubsystem,export

Página 240 - Not Usablestatus

DS300f G2 Series User Manual 73vIewInG current backGrounD actIvItIeSTo view a list of current background activities:1. Click the Administration tab.

Página 241

DS300f G2 Series User Manual 2about thIs ManualThis Product Manual describes how to setup, use, and maintain the ASUS DS300f G2 Series and DS300j G2

Página 242 - InstallInG perfeCtpath

DS300f G2 Series User Manual 74chanGInG a backGrounD actIvIty ScheDuleTo change an existing scheduled background activity:1. Click the Administratio

Página 243 - StartInG PerfectPath vIew

DS300f G2 Series User Manual 75meDIa PatrolMedia Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive. Media P

Página 244 - IewInG Path ProPertIeS

DS300f G2 Series User Manual 763. Click the Settings button.4. Click the Logical Drive Initialization Rate drop-down menu and choose a rate:• Low

Página 245 - IewInG eventS

DS300f G2 Series User Manual 774. Make the following settings are required:•ClickthePDMRatedrop-downmenuandchoosearate:Low–Fewersystem

Página 246

DS300f G2 Series User Manual 78ManaGInG storaGe servICesStorage service management includes:• "Viewing a List of Services" on page 78• &q

Página 247 - PDo removal

DS300f G2 Series User Manual 79SlP ServIceService Location Protocol (SLP) discovers services over the Internet. SLP applies to IPv4 protocol only.sto

Página 248 - Performance tab refreSh rate

DS300f G2 Series User Manual 80telnet ServIceTelnet service enables you to access the RAID subsystem’s Command Line Interface (CLI) through a network

Página 249 - SavInG SyStem InformatIon

DS300f G2 Series User Manual 81MAking ssh settingsTo change SSH service settings:1. Click the Administration tab.2. Click the Services icon.3. Cli

Página 250

DS300f G2 Series User Manual 82deleting An snMP trAP sinkTo delete a trap sink:1. Click the Administration tab.2. Click the Services icon.3. Click

Página 251 - PreferreD methoD

DS300f G2 Series User Manual 83MAking netsend settingsTo change Netsend service settings:1. Click the Administration tab.2. Click the Services icon

Página 252

DS300f G2 Series User Manual 3asus ds300f G2 overvIewAll ASUS Storage ASUS DS300f G2 and DS300j G2 models support use of 6 Gb/s SAS and SATA disks.Th

Página 253 - InStallInG PackaGeS

DS300f G2 Series User Manual 84workInG wIth the event vIewerWorking with the Event Viewer includes the following functions:• "Viewing Runtime E

Página 254 - SuSe SyStemS

DS300f G2 Series User Manual 85vIewInG nvram eventSThis screen displays a list of and information about the most important events over multiple subsy

Página 255 - SettInG the Daemon to run

DS300f G2 Series User Manual 866. Click the Select Physical Drives button and check the boxes for the physical drives you want to see.•Totalofall

Página 256

DS300f G2 Series User Manual 87ManaGInG physICal drIvesPhysical drive management includes:Forphysicaldisktroubleshooting,see"Physical Drive

Página 257 - SuSe lInux SleS 10 SP3

DS300f G2 Series User Manual 88Advanced information for SAS physical drives includes:makInG Global PhySIcal DrIve SettInGSTo make global physical dri

Página 258

DS300f G2 Series User Manual 89SavInG the PhySIcal DrIve Smart loGTo save the physical drive SMART Log:1. Click the Device tab.2. Click the Physica

Página 259

DS300f G2 Series User Manual 90forcInG a PhySIcal DrIve offlIneThis feature applies only to physical drives assigned to disk arrays.CautionForcing a

Página 260 - Inux MpIo: known Issues

DS300f G2 Series User Manual 91ManaGInG dIsk arraysFordiskarraytroubleshooting,see"Disk Array and Logical Drive Problems" on page <

Página 261

DS300f G2 Series User Manual 92disk ArrAy oPerAtionAl stAtus• OK –Thisisthenormalstateofalogicaldrive.WhenalogicaldriveisFunctional,

Página 262

DS300f G2 Series User Manual 93makInG DISk array SettInGSTo make disk array settings:1. Click the Storage tab.2. Click the Disk Array icon.The list

Comentários a estes Manuais