CFGGEN Commands A-17
Version 1.1 Copyright © 2006, 2007 by LSI Logic Corporation. All rights reserved.
If there are any existing IM, IME, or IS volumes when this command is
run, the user is notified via an output message, no action is taken, and
CFGGEN returns FAILURE. If Integrated RAID is already disabled when
this command is run, CFGGEN returns SUCCESS.
Command Line
cfggen <controller #> disableir
Parameters
<controller #> Number of the SAS controller targeted by this
command.
Program Return Value
0x00 SUCCESS: command completed successfully.
0x01 FAILURE: bad command line arguments or operational failure.
A.3.12 ENABLEIR Command (EFI Version Only)
The ENABLEIR command, which is currently supported only in the EFI
version of CFGGEN, enables Integrated RAID functionality on the
supported SAS controller chips. This is done by clearing the
MPI_IOUNITPAGE1_DISABLE_IR bit in the IO Unit 1 MPT Configuration
Page.
If there are any existing IM, IME, or IS volumes when this command is
run, the user is notified via an output message, no action is taken, and
CFGGEN returns SUCCESS. If Integrated RAID is already enabled when
this command is run, CFGGEN returns SUCCESS.
Command Line
cfggen <controller #> enableir
Parameters
<controller #> Number of the SAS controller targeted by this
command.